fingertips. Modular in structure, the Flame-Monitor system allows you to custom design your control system to match your specific burner/boiler fuel firing characteristics. The complete burner system includes a Flame-Monitor control, keypad/ display module and a full library of programmer modules, amplifier modules and associated scanners. Modernization adapters are available to easily upgrade from an older Fireye control system. Current status for each burner plus historical data relating to burner cycles, hours of operation, the number and cause of safety lockouts are readily available locally on the ED510 keypad/display module.
|
Fireye E110 Description
The Fireye E110 FLAME-MONITOR™ System is a microprocessor based burner management control system designed to provide the proper burner sequencing, ignition and flame monitoring protection on automatically ignited oil, gas, and combination fuel burners. In conjunction with limit and operating controls, it programs the burner/blower motor, ignition and fuel valves to provide for proper and safe burner operation. The control also provides current operating status and lockout information in the event of a safety shutdown. The manner in which this information is displayed is dependent on the type of programmer (EP or EPD) and display module (ED510 or ED500).* Refer to Flame-Monitor PROGRAMMER SELECTION later in this document for the various combinations of programmer and display modules.
The E110 consists of the EB700 chassis, dust cover, and shortened mounting screw (P/N 48-1836). The display module (ED510), if required, must be ordered separately. Interchangeable programmer and flame amplifier modules allow for complete versatility in selection of control function, timing, and flame scanning means. Functions such as pre-purge, recycling interlocks, high fire proving interlock, and trial for ignition timing of the pilot and main flame are determined by the programmer module. The E110 Flame-Monitor can be used with ultra-violet,
auto-check infrared, flame rod, or self-check ultraviolet flame scanners by choosing the proper amplifier module.
The eighteen (18) terminal wiring base allows for many functional circuits including motors, valves, and ignition transformers as well as multiple interlocks such as high purge, low purge, fuel valve and running interlock circuits. The E110 uses the same wiring base as the Fireye E100 Flame-Monitor control, D Series and C Series Controls and is directly interchangeable with most models without rewiring.
The E110 consists of the EB700 chassis, dust cover, and shortened mounting screw (P/N 48-1836). The display module (ED510), if required, must be ordered separately. Interchangeable programmer and flame amplifier modules allow for complete versatility in selection of control function, timing, and flame scanning means. Functions such as pre-purge, recycling interlocks, high fire proving interlock, and trial for ignition timing of the pilot and main flame are determined by the programmer module. The E110 Flame-Monitor can be used with ultra-violet,
auto-check infrared, flame rod, or self-check ultraviolet flame scanners by choosing the proper amplifier module.
The eighteen (18) terminal wiring base allows for many functional circuits including motors, valves, and ignition transformers as well as multiple interlocks such as high purge, low purge, fuel valve and running interlock circuits. The E110 uses the same wiring base as the Fireye E100 Flame-Monitor control, D Series and C Series Controls and is directly interchangeable with most models without rewiring.
Features of the Flame-Monitor Control System Include:
|
|
Fireye Display Module - ED510
The ED510 Display Module is designed to operate with the FLAME-MONITOR Burner Management Control System using the EP style programmer modules as well as the MicroM series of controls.
The ED510 display module provides the following features and capabilities: Two (2) line by sixteen (16) character backlit
LCD display. Continuous display of current burner operating status, including first out annunciation in the event of a lockout condition.Three (3) key, tactile dome keypad to provide historical information of the burner, last six (6) lockout conditions (with burner cycle and burner hour time stamp), assign messages associated with the operation of the E300 expansion module, and diagnostic messages. Design mounts directly onto the front face of the EP style programmers. RJ style connector for connection to the EP programmer. Remote display capability with the EP style programmers and MicroM system using standard DIN sized opening and remote mounting kit. Weather proof housing (NEMA 4 using remote
mounting kit 129-145-1, -2).
The ED510 display module provides the following features and capabilities: Two (2) line by sixteen (16) character backlit
LCD display. Continuous display of current burner operating status, including first out annunciation in the event of a lockout condition.Three (3) key, tactile dome keypad to provide historical information of the burner, last six (6) lockout conditions (with burner cycle and burner hour time stamp), assign messages associated with the operation of the E300 expansion module, and diagnostic messages. Design mounts directly onto the front face of the EP style programmers. RJ style connector for connection to the EP programmer. Remote display capability with the EP style programmers and MicroM system using standard DIN sized opening and remote mounting kit. Weather proof housing (NEMA 4 using remote
mounting kit 129-145-1, -2).
Flame Amplifier Selection - Fireye Description use with Scanner
EUV1
E1R1 E1R2 E1R3 ERT1 EUVS4 |
Standard UV Amplifier
Autocheck Infrared Amplifier Autocheck Infrared Amplifier Autocheck Infrared Amplifier Rectification Amplifier Self-Check UV Amplifier |
UV1A, UV8A 45UV3, UV2
48PT2 48PT2 48PT2 69ND1 45UV5-1007/1008/1009 |
Scanner Selection
48PT2-1003
48PT2-9003 48PT2-1007 48PT2-9007 4-263-1 |
Infrared 1/2" straight mount 96" TC-ER
Infrared 1/2" 90 angle mount 96" TC-ER Infrared 1/2" straight mount 48" TC-ER Infrared 1/2" 90 angle mount 48" TC-ER Replacement photo detector |
E1R1, E1R2, or E1R3
E1R1, E1R2, or E1R3 E1R1, E1R2, or E1R3 E1R1, E1R2, or E1R3 E1R1, E1R2, or E1R3 |
UV1A3
UV1A6 UV8A UV2 UV2A6 45UV3-1050 UV90-3 UV90-6 UV90-9 |
UV 1/2" straight 36" TC-ER cable
UV 1/2" straight 72" TC-ER cable UV 1/2" 90 head 72" unshielded leads UV 3/8" straight 36" TC-ER cable UV 3/8" straight 72" TC-ER cable UV 3/4" cast aluminum housing 8' cable UV 90° lateral view with 36” flex conduit UV 90° lateral view with 72” flex conduit UV 90° lateral view with 108” flex conduit |
EUV1
EUV1 EUV1 EUV1 EUV1 EUV1 EUV1 EUV1 EUV1 |
69ND1-1000K4
69ND1-1000K6 69ND1-1000K8 |
Flame rod 12", 1/2" N.P.T.mount
Flame rod 18", 1/2" N.P.T.mount Flame rod 24", 1/2" N.P.T.mount |
ERT1
ERT1 ERT1 |
45UV5-1007
45UV5-1008 45UV5-1009 4-314-1 |
Self-check UV 1" British thread mounts, 230V
Self-check UV 1" British thread mounts, 120V Self-check UV 1" N.P.T. threads, 120V Replacement UV tube |
EUVS4
EUVS4 EUVS4 EUVS4 |
Flame-Monitor Programmer Selection
The functional operation, flame failure response time, purge timings, firing rate motor circuit, trial for ignition timings, recycling function and display messages are determined by the programmer.
Part #EP160
EP161 EP165 EP166 EP170 EP260 EP265 EP270 EP380 EP381 EP382 EP387 EP390 |
Programmer DescriptionProgrammer. Selectable purge (30 sec min.) 10 and 15 sec. TFI, non-recycle
Programmer. Selectable purge (30 sec min.) 10 and 30 sec. TFI, non-recycle Programmer. Selectable purge (30 sec min.) pilot stabilization, non-recycle, 10 and 10 sec TFI Programmer. Selectable purge (30 sec min.) pilot stabilization, non-recycle, 10 and 15 sec TFI Programmer. Selectable purge (30 sec min.) 5 and 10 sec. TFI, non-recycle, early spark term. Programmer. Selectable purge (30 sec min.) 10 and 15 sec. TFI, recycle Programmer. Selectable purge (30 sec min.) pilot stabilization, recycle, 10 and 10 sec TFI Programmer. Selectable purge (30 sec min.) 5 and 10 sec. TFI, recycle, early spark term Programmer. Selectable purge (30 sec min.) 5 and 10 sec. TFI, selectable recycle, no modulation Programmer. Selectable purge (15 sec min.) 5 and 10 sec. TFI, selectable recycle/non-recycle, no modulation Programmer. Selectable purge (00 sec min.) 5 and 10 sec. TFI, selectable recycle/non-recycle, no modulation Programmer. Selectable purge (15 sec min.) 5 and 10 sec. TFI, selectable recycle/non-recycle, no modulation, MD circuit hold Programmer. Selectable purge (90 sec min.) 5 and 10 sec. TFI, selectable recycle/non-recycle, no modulation |